Powerline Converters

For ease in data transmission use Canopus Instruments powerline converters. The powerline converters offered by Canopus instruments are fully compatible with minimum dimensions providing simple solutions. Get in touch with us to know the details of the product.

Download PDF

The AC Voltage Isolators ( 3 Port ) can be used in Potential Transformer (PT) signal conditioning applications. The AC voltage output (e.g. 0– 100 / 300 / 500 VAC) of a PT can be directly connected to the input of the unit which provides isolated analog DC voltage or current output that is linearly proportional to the input.

The AC Current Isolators ( 3 Port ) are used in Current Transformer (CT) signal conditioning applications. The AC current output (e.g. 0 – 1 Amp. or 0 – 5 Amp.) of a CT can be directly connected to the input of the unit which provides isolated analog DC voltage or current output that is linearly proportional to the input

This enables ease of data transmission as well as interfacing to standard measuring devices such as Analog input modules of PLC & DCS systems. These units are used in AC Power line voltage / AC Power line current measurement and monitoring applications.

The unit provides 3 -port 2 KV isolation between input, output and supply. Multiple Isolated Outputs can also be obtained to suit application requirement.

The module options are available which operate on 24VDC supply and on Universal AC/DC supply voltages of 90 – 270 V AC, 50/60 Hz or 100-250VDC. The use of switching power supply improves power efficiency and reduces internal heat losses of the module.

These units are compact, light weight and are suitable for mounting on 35 mm DIN std. rail as well as on base plate.

Ordering Information

μ3.0 I/P Signal I/P Signal Supply I/P Signal Range O/P Signal Range No. of O/P’s (Extension required only when 2nd & 3rd O/P’s are available)
μ3.0 I/P O/P XXX XX XX XX
μ3.0

Iac

Vdc

V

I

24VDC : 2D

90-270VAC : U

OR

100-250VDC

0-1A : 01 0 -5V : 05

0-10V :10

4-20mA :42

0-20mA :20

V : 2nd O/P V : 0-10V
0-5A: 05 2V : 2nd O/P V: 0-10V
3rd O/P V: 0-10V
0 -8A :08 I : 2nd O/P I: 4-20mA
0 -100V : 100 2I : 2nd O/P I: 4-20mA
3rd O/P I : 4-20mA
0 -300V : 300 VI : 2nd O/P V: 0-10V
3rd O/P I: 4-20mA
0 -500V : 500

Frequent Searches for Powerline Converters

Current Measurement Unit India, Current Measurement Device India, Powerline Converter India, Powerline Converter Pune, Powerline Converter New Delhi, Powerline Converter Bangalore, Powerline Converter Mumbai, Powerline Converter Chennai, Powerline Converter Kolkata, Powerline Converter Hyderabad, Powerline Converter Ahmedabad, Powerline Converter Nashik, Current Measurement Instrument Pune
Download PDF

  • Input Options:
    AC Current: 0 – 1A, 0 – 5A, 0 – 8A.
    AC Voltage: 0 – 100V, 0 – 300V, 0 – 500V.
  • Industry Standard Output: 1-5V, 0 – 5V, 0 – 10V, 4-20mA, 0 – 20mA.
  • Power supply options:
    24VDC
    90 – 270VAC, 50Hz/60Hz or 100 – 250VDC
  • Reduced heat loss due to improved Power Supply efficiency.
  • Response Time <100mSec.
  • Low Noise & Low drift for long term stability.
  • 2 KV 3 Port Isolation.
  • Performance guaranteed from 0 -55 Deg C.
  • Single, Dual & Triple Isolated Output versions available.
  • Upto 8 nos. of Isolated Outputs can be generated using back-plane expansion.

 

Download PDF

1. Power Supply : 24VDC Supply Power Supply Voltage Typical : 24 V DC
Tolerance: 18 –36VDC
Power Supply Current 200 mA (max.) .
Power Consumption (Approx.) 2 Watt (Single Output type)
4 Watt (Dual Output type)
5 Watt (Triple Output type)
Universal Supply Power Supply voltage 90 –270VAC; 50/60Hz OR
100-250VDC
Power Consumption(Approx.) 9 VA Approx
2. Input signal AC Current
AC Voltage
0 – 1A , 0 – 5A , 0 – 8A
0 -100V, 0-300V,0-500V
Max. permissible Limit For Current Input : 10 A AC
For Voltage Input : 750 VAC
For Current Input
For Voltage Input
CT Burden < 0.5VA
Impedance >1 M Ohms
3. Output signal DC current or DC voltage 0 –20 mA or 4 – 20 mA or 0-10V DC
Single Output : Any one of above
Dual Output : Any two of above
Triple Output : Any two of above
Output limit For Current Output 30 mA
For voltage Output +/-15 V
Max. load resistance For Current Output < 500 Ohms
For Voltage Output > 1K Ohms
Response Time Typically : <100 ms
4. Accuracy data At 25 0 C ambient Temp. +/- 0.25 % of FS
Limits over Temp. +/- 0.5% of FS
Range Drift Temp. + 0.005% / Deg. C/
Coefficient Linearity 0.1 % of FS
5. Ambient conditions Climatic rating Design as per : As per IEC 60068 – 2-30
Operating temp. -10 to + 60 Deg C
Storage temp. – 20 to + 85 Deg C
Relative Humidity R.H = 93 + 3 % ,
Design as per Vibration Standard Frequency : 10 – 150 Hz
Displacement : 0.75 mm or
acceleration : 1.5 g,
No. of sweep/axis : 20,
Axis : 3 (x, y & z)
Design as per Shock Standard 40g. 11 ms, half sine pulse & 18 shocks,
3 shock in each sense.
As per IEC 61010-1
6. Safety Isolation Level Between I/P & O/P
2KV RMS Between I/P, O/P & Supply
7. Installation Data Cooling Forced cooling not required
Material of housing Polyamide PA 6.6
VO (UL 94).
Green Colour
Mechanical Size For Single Input Single Output
W – 22.5 X H – 100 XD- 110 mm
For Single Input Dual/Triple Output
W – 45 X H – 100 XD- 110 mm
Mounting 35 mm DIN Rail Mounted
Mounting position Horizontal OR Vertical.
Connectors Green Colour , 5.08 mm Pitch , 16 A
Connection Screw terminal suitable for 0.2 to 2.5 mm standard wires

 

Download PDF

Reviews

There are no reviews yet.

Be the first to review “Powerline Converters”

Your email address will not be published. Required fields are marked *

Translate »