Prifibus Devices (Ci-800DP Series)
/ Ci - 800DP Remote Thermocouple Cluster Transmitter Back
 
 
   

The Remote Thermocouple Cluster Transmitter is an innovative product from Canopus Instruments suitable for transmitting a variety of Thermocouple signals from a cluster of process units on a single two wire Profibus-DP bus system. The transmitter can handle 8 Thermocouple signals with channel wise range & diagnostics selection through software. The Thermocouple types R , J , K , T & S can be selected through software. Algorithms are provided for Cold junction compensation & Thermocouple non-linearity compensation . The integrated Profibus DP communications interface with configurable baud rates from 9.6Kbps to 12Mbps gives flexibility in connectivity to any Profibus DP Master.

 
     
 

The complete software configurability for input signal types, range & diagnostics without jumper or DIP switch settings and the incorporation of the industry standard open fieldbus system PROFIBUS-DP facilitates quick set-up & integration with the main control system.

 
 

 

 
 

The transmitter is housed in a ABS Plastic enclosure with integrated 2.5 mm sq. terminal blocks for direct field cable termination. The transmitter can be mounted on a 35 mm standard DIN rail . A direct field mountable design in a die cast Aluminium enclosure is under development. This shall be suitable for mounting on a MS / SS pipe of suitable diameter.

 
 

 

 
  User benefits  
 

The transmitter provides enormous cost savings for those users wishing to migrate to a Fieldbus system from the traditional concept of direct field cabling of temperature sensors. Direct cost savings accrue from reduced lengths of Thermocouple compensation cables as large distances can be covered with the Profibus-DP fieldbus system. The complete software configurability of the device facilitates quick system set-up & integration with the main control system resulting in reducing the system commissioning time.

 
     
  Technical specifications  
     
 
Specification Module data
No. of Thermocouple inputs 8 nos.
Thermocouple types K , J , R , S & T
Input Sensor & range selection thru’ Software (GSD file) - max. 1800 Deg C
Input measurement accuracy 0.25% of span
Conversion time per channel 500 ms
Linearity error 0.05%
Temperature drift 0.0001% per deg C
Repeatability 0.015 %
Input resistance 1 G Ohms
Current consumption at 24VDC 125 mA
Max. signal cable length 200 m for shielded cable
Terminals Screwed type ; suitable for 2.5 mm sq. wires
Module expansion Through local port ; upto modules can be connected
Communication port Profibus – DP Slave
Data transmission rate Max. 12 Mb
Status indication LEDs

8 x Red LEDs for channel fault indication
Red LED for Bus fault
Dual LED for Card health (Red–faulty module, Green–healthy module )
Red LED for Module fault
Yellow LED for Profibus DP Communication active

Power supply 18 – 30 VDC
Operating temperature range 0 – 60 deg C
Operating relative humidity 0 – 95% RH ( non-condensing )
Enclosure ABS plastic
Mounting 35 mm DIN rail
Dimensions (WxHxD) mm 110H x 155W x 65D
Weight 540 gms
   
 
     
 

Note : Due to a regular product improvements being undertaken by us , all technical specifications are subject to
change without notice

 
     
 