Home About Us Products Facilities Technology Application Notes Clients News  
 
 
 
Process Transmitter / Load Cell Amplifier Back
 
     
  Features  
     
 
Precision Load Cell Amplifier.
Built in precision reference generator for excitation.
Improved performance.
 
a o Low peak and RMS noise.
b o Low drift input circuitry for long term stability.
Accuracy + 1.0 % of RS.
230 V AC / 24 VDC Supply options.
DIN rail mounting.
 
     
  Applications  
     
 
For Weighing & Batching application in industries e.g. Cement, Steel, Chemical & Pharma.
Reduction of electrical noise in measured signals.
Signal transmission over long distances in large plants.
 
     
 
Load Cell Isolator variants
Variants in this series are divided into following types :
Load Cell / Voltage
Load Cell / Current
 
     
 

The Load Cell Amplifier is a precision amplifier for conditioning the milivolt output from a Lad Cell so that it can be given as an input to the microprocessor based Interface Unit. Alternatively the output can also be given to the analog input module of a PLC or DCS system in the form of standard 0 - 10V voltage signal or 4 - 20mA current loop signal. In addition, the unit has a built in 10 Volts precision reference generator, which is used for excitation of the Load Cell. These amplifier units are extremely stable and accurate for long term measurement applications and can also be calibrated to suit the Load Cell response characteristics so that maximum sensitivity is available in the measurement range.

 
     
 
Module LCA / V LCA / I

Input Range

Reference Voltage input Resistance

0 - 10mV or 0 - 20 mV OR 0 - 30 mV DC Differential input from Load Cell.

10 V DC, 50 mA
1M Ohms

0 - 10mV or 0 - 20 mV OR 0 - 30 mV DC Differential input from Load Cell.

10 V DC, 50 mA
1M Ohms

Isolation Level. CMV (I/P TO O/P)

2000 Vms max.

2000 V rms max.

Accuracy
Non-Linearity
Temp. Drift
Response Time

+/- 0.1% of Span
+/- 0.1% of Span
0.01% /0 C
< 1 Sec

+/- 0.1% of Span
+/- 0.1% of Span
0.01% /0 C
< 1 Sec

Output Range

0-10 V DC

4 - 20 mA DC

Power Supply Voltage

230 VAC / 24 VDC

230 VAC / 24 VDC

Mechanical Size Enclosure

W - 100 mm X H - 75 mm X D - 110 mm Plastic, 35 mm DIN Rail Mounted.

W - 100 mm X H - 75 mm X D - 110 mm Plastic, 35 mm DIN Rail Mounted.

Environmental Operating temp.range Relative Humidity

0-60 0C
0 - 90% RH noncodensing

0-60 0C
0 - 90% RH noncodensing

 
     
 
 